feat: CPU & RAM per server with a catalogue of Intel and AMD server CPUs
Devices get a CPU & RAM panel: CPU model from a built-in catalogue of over 700 Intel Xeon and AMD Opteron/EPYC server CPUs since 2012 (cores, threads, base/turbo clock, TDP, socket, year, max sockets; checked against Intel ARK, AMD and server vendor data), CPU count and RAM with modules, type and speed. The catalogue is loaded by migration 0011, can be edited and extended in the UI and refreshed with netbox_utilities_cpu_catalog. Virtualization: clusters show their capacity (cores, threads and RAM of the hosts against the vCPUs and memory of the VMs, vCPU:core ratio, RAM allocation, N+1 reserve) with a per-host table, hosts list their VMs and VMs show the CPU of their host. Optional columns for the device and cluster lists, CSV import, REST API, GraphQL and search are included. The plugin menu is now called "Hardware". Co-Authored-By: Claude Opus 5.5 <[email protected]>
This commit is contained in:
1 parent
8396b7c64a
commit
c8b581089c
31 files changed
+2849
-17
No files matched your search
@@ -47,6 +47,7 @@ Plugin settings:
|
||||
- The B-side device selection of a cable can be pre-filtered by tenant group, tenant and site.
|
||||
- A **Prefix** column (first word of the site name) for device and rack lists, including sorting and filtering.
|
||||
- A **Disks** tab for servers, NAS, SAN and MSA devices: slot layout, disks, RAID groups, warranty and age warnings, replacement history, CSV import, HPE MSA disk export import, REST API and GraphQL.
|
||||
- **CPU & RAM** per server from a built-in catalogue of 700+ Intel and AMD server CPUs since 2012, with cluster capacity and overcommit for NetBox virtualization.
|
||||
|
||||
Navigation settings are stored per user. The active tenant or tenant-group
|
||||
selection is stored in the browser session.
|
||||
@@ -218,6 +219,9 @@ sudo systemctl restart netbox netbox-rq
|
||||
| `disk_device_roles` | `["Server", "NAS", "SAN", "MSA"]` | Device role names (case-insensitive) that get the **Disks** tab |
|
||||
| `disk_age_warning_years` | `5` | Warn about disks older than this (manufacture date, otherwise install date) |
|
||||
| `disk_warranty_warning_days` | `90` | Warn this many days before the warranty ends |
|
||||
| `hardware_enabled` | `True` | **CPU & RAM** panels, catalogue, columns and cluster capacity |
|
||||
| `hardware_device_roles` | `["Server"]` | Device roles (case-insensitive) that show the **CPU & RAM** panel; cluster hosts always show it |
|
||||
| `hardware_vcpu_ratio_warning` | `4` | Warn when a host or cluster has more vCPUs per physical core |
|
||||
|
||||
## Usage
|
||||
|
||||
@@ -269,7 +273,7 @@ can start at slot 0 again.
|
||||
for the device type. The next device of the same type offers **Apply
|
||||
template**, which creates all stored areas with one click; on a device that
|
||||
already has areas, the button adds the missing ones. Templates are managed under
|
||||
**Disks > Disk templates** in the main menu.
|
||||
**Hardware > Disk templates** in the main menu.
|
||||
|
||||
**Slot grid.** Each area is drawn as its own grid and coloured by
|
||||
status (active, hot spare, failed, planned). A warning icon marks disks with
|
||||
@@ -312,10 +316,11 @@ capacity, the usable RAID capacity, spares and failed disks. The warnings panel
|
||||
lists failed disks, expired warranties, warranties ending within
|
||||
`disk_warranty_warning_days` and disks older than `disk_age_warning_years`.
|
||||
|
||||
**Main menu.** The plugin adds its own **Disks** menu with the entries
|
||||
**Disks**, **RAID groups** and **Disk templates**.
|
||||
**Main menu.** The plugin adds its own **Hardware** menu with the entries
|
||||
**Disks**, **RAID groups** and **Disk templates**, plus **CPU & RAM** and
|
||||
**CPU models** (see below).
|
||||
|
||||
**Disks grouped by device.** **Disks > Disks** shows all disks grouped by device.
|
||||
**Disks grouped by device.** **Hardware > Disks** shows all disks grouped by device.
|
||||
Each device is a collapsible section whose header shows the device, role, site,
|
||||
tenant, number of disks, raw capacity, failed disks and warnings, plus a link to
|
||||
the device's **Disks** tab. The page offers a search (serial number, model,
|
||||
@@ -351,7 +356,7 @@ srv-01,Front,1,spare,ssd,sas,Samsung,PM1643a,1.92 TB,S4XXNA0R123457,2029-05-31
|
||||
srv-01,PCIe,0,active,nvme,nvme,Samsung,PM9A3,3.84 TB,S64XNA0T654321,2030-01-31
|
||||
```
|
||||
|
||||
**HPE MSA import.** The *HPE MSA export* button next to **Disks > Disks** (also
|
||||
**HPE MSA import.** The *HPE MSA export* button next to **Hardware > Disks** (also
|
||||
*MSA import* in a device's **Disks** tab) reads the CSV disk export of an HPE MSA
|
||||
(*Pools → Disks*, export to CSV). The `Location` column (`1.4` = enclosure 1,
|
||||
slot 4) defines the enclosures; in the next step each enclosure (shelf) is
|
||||
@@ -403,6 +408,90 @@ The HPE MSA import requires `netbox_utilities.add_disk`; updating or replacing
|
||||
existing disks additionally requires `netbox_utilities.change_disk`, and creating
|
||||
RAID groups `netbox_utilities.add_raidgroup` (otherwise they are skipped).
|
||||
|
||||
### CPU & RAM
|
||||
|
||||
Servers and virtualization hosts get a **CPU & RAM** panel on the device page.
|
||||
It is shown for devices whose role is listed in `hardware_device_roles`, for
|
||||
every device assigned to a cluster, and for every device that already has CPU &
|
||||
RAM recorded. **Add** opens a form with:
|
||||
|
||||
- **CPU model**: a searchable select over the catalogue. Typing `6338`,
|
||||
`Gold 6338` or `epyc 7543` is enough; each entry shows cores, threads and
|
||||
base/turbo clock.
|
||||
- **Number of CPUs** (populated sockets). It is checked against the maximum
|
||||
socket count of the model, e.g. EPYC "P" models are single-socket only.
|
||||
- **RAM**: number and size of the modules, total RAM (calculated from modules ×
|
||||
size when left empty), type (DDR3/DDR4/DDR5) and speed in MT/s.
|
||||
|
||||
The panel then shows e.g. *2 × Intel Xeon Gold 6338 · 64 cores / 128 threads ·
|
||||
1 TB (16 × 64 GB DDR4-3200)*. The device list offers the optional columns
|
||||
**CPU**, **Cores / Threads** and **RAM** under **Configure Table**.
|
||||
|
||||
**CPU catalogue.** **Hardware > CPU models** lists about 700 server CPUs:
|
||||
|
||||
| Vendor | Families |
|
||||
|---|---|
|
||||
| Intel | Xeon E5-2600/2400/4600/1600 v1–v4, E7 v2–v4, E3-1200 v2–v6, Xeon E-2100 to E-2400, Xeon 6300P, Xeon Scalable 1st–5th Gen (Skylake to Emerald Rapids), Xeon 6 (Sierra Forest, Granite Rapids), Xeon 6+ (Clearwater Forest) |
|
||||
| AMD | Opteron 4300/6300, EPYC 7001/7002/7003 (incl. F and X models), 9004 (Genoa, Genoa-X, Bergamo), 8004, 4004, 4005, 9005 (Turin) |
|
||||
|
||||
Each entry has cores, threads, base and turbo clock, TDP, socket, launch year
|
||||
and maximum socket count. The values were checked against Intel ARK, AMD and
|
||||
server vendor specifications. Missing models can be added in the UI or by CSV
|
||||
import; catalogue entries can be edited, too. The catalogue is loaded by the
|
||||
migration and refreshed after a plugin update with:
|
||||
|
||||
```bash
|
||||
cd /opt/netbox/netbox
|
||||
../venv/bin/python manage.py netbox_utilities_cpu_catalog # add new models, keep edited ones
|
||||
../venv/bin/python manage.py netbox_utilities_cpu_catalog --force # also reset edited catalogue entries
|
||||
```
|
||||
|
||||
Models you created yourself are never changed by the command.
|
||||
|
||||
**Virtualization.** CPU & RAM work together with NetBox clusters and virtual
|
||||
machines (vCPUs and memory of the VM):
|
||||
|
||||
- **Cluster page:** a **Capacity (CPU & RAM)** panel sums the hosts (devices
|
||||
of the cluster) and compares them with the VMs: physical cores/threads and
|
||||
RAM, allocated vCPUs and RAM, the vCPU-to-core ratio, RAM allocation in
|
||||
percent and the RAM that remains if the largest host fails (N+1). A table
|
||||
lists every host with its CPU, VMs, ratio and RAM usage; hosts without CPU &
|
||||
RAM are flagged with a link to record them.
|
||||
- **Host (device) page:** the CPU & RAM panel adds the VMs running on that
|
||||
host (VMs whose *Device* is set) with the same figures.
|
||||
- **VM page:** a **Host hardware** panel shows the CPU of the host, or of the
|
||||
cluster hosts if the VM has no fixed host, and warns if the VM has more
|
||||
vCPUs than the host has threads.
|
||||
- **Cluster list:** the optional column **vCPU : core · RAM** shows the ratio
|
||||
and RAM allocation per cluster.
|
||||
|
||||
Warnings appear when VMs are allocated more RAM than the hosts have, when the
|
||||
RAM no longer fits after the failure of the largest host, and when the vCPU
|
||||
ratio exceeds `hardware_vcpu_ratio_warning`. VMs with the status *Offline* or
|
||||
*Decommissioning* are not counted. VM memory is read in MB as NetBox stores it.
|
||||
|
||||
**CSV import.** **Hardware > CPU & RAM > Import** accepts `device` (name),
|
||||
`cpu` (catalogue model name, e.g. `Xeon Gold 6338`), `cpu_count`, `memory_gb`,
|
||||
`memory_type` (`ddr3`, `ddr4`, `ddr5`), `memory_modules`, `memory_module_gb`,
|
||||
`memory_speed_mts`, `description`, `comments` and `tags`.
|
||||
|
||||
```csv
|
||||
device,cpu,cpu_count,memory_modules,memory_module_gb,memory_type,memory_speed_mts
|
||||
esx01,Xeon Gold 6338,2,16,64,ddr4,3200
|
||||
esx02,EPYC 9354,2,24,32,ddr5,4800
|
||||
```
|
||||
|
||||
**REST API and GraphQL.** `/api/plugins/utilities/cpu-models/` and
|
||||
`/api/plugins/utilities/device-hardware/` (with read-only `total_cores` and
|
||||
`total_threads`); filters include `?q=6338`, `?manufacturer=amd`,
|
||||
`?cores__gte=32`, `?cluster_id=4` and `?cpu_id=17`. GraphQL offers
|
||||
`netbox_utilities_cpu_model(_list)` and `netbox_utilities_device_hardware(_list)`.
|
||||
|
||||
**Permissions.** The panels require `netbox_utilities.view_devicehardware`;
|
||||
recording and editing use `netbox_utilities.add_devicehardware` and
|
||||
`netbox_utilities.change_devicehardware`. The catalogue uses the
|
||||
`netbox_utilities.*_cpumodel` permissions.
|
||||
|
||||
### Pre-filter for the B-side of a cable
|
||||
|
||||
When creating or editing a cable, the **B-side** section shows optional
|
||||
|
||||
Reference in new issue
Block a user