v4.17.0
Co-Authored-By: Claude Opus 5.5 <[email protected]>
NetBox Synchronizer
Windows desktop application that documents virtual machines from VMware vSphere and Proxmox VE, HPE/Aruba switches and Windows clients in NetBox.
| Type | Desktop application (Python, PySide6) |
| Platform | Windows |
| Repository | https://git.mrblake.cc/MrBlake/NetBox-VM-Import-Desktop |
Features
General
- Customer profiles with NetBox target, virtualisation sources and switch credentials; switch between them in the sidebar
- Automatic saving; passwords, tokens and secrets are encrypted with Windows DPAPI
- All network access runs in the background — the window stays responsive and operations can be cancelled
- Light and dark theme (optionally following Windows)
- Log with filter, search and export, plus a rotating log file under
%APPDATA%\NetBox VM Import\logs - Keyboard shortcuts:
Ctrl+1…8navigation,Ctrl+9settings,F5reload/read,Ctrl+Fsearch - Updates from the Gitea releases: checked on start (can be switched off in the settings, or run on demand); after confirmation the installed version runs the new setup silently and the portable EXE replaces itself, then the application restarts. A version can be skipped
Virtual machines
- Multiple VMware and Proxmox sources per profile, read in parallel; connection test directly in the dialog
- QEMU/KVM VMs and optionally LXC containers; IP addresses via VMware Tools or the QEMU guest agent
- Table with search, filters (source, status, "new"/"already in NetBox") and multi-selection
- Automatic cluster mapping: each vCenter/ESXi or Proxmox cluster is mapped to the NetBox cluster with the same (or a uniquely similar) name; manual mappings are remembered in the profile, and missing clusters can be created in NetBox directly
- Four-step import wizard: Target (cluster mapping, tenant preselected from the cluster, VRF or global) → Networks (check missing prefixes with size and VRF, create new VRFs directly) → Review (summary of all changes) → Import (progress, live log, cancel)
- VMs are matched uniquely per cluster; existing prefixes are reused
- MAC addresses are set correctly on NetBox ≥ 4.2 (separate MAC model)
Switches (Aruba CX, ArubaOS-Switch/ProCurve, HPE Comware)
- Add several NetBox devices in one step — host taken from the primary IP, platform suggested from model/manufacturer; members of a NetBox virtual chassis are added once, through the chassis master
- Platform "detect automatically" via SSH
- Parallel SSH queries; SSH host keys are stored on first contact and verified afterwards
- Interfaces, interface IP addresses and LLDP/CDP neighbours
- Preview before writing: all changes are computed as a dry run and only sent after confirmation
- Interface types from device type templates are left untouched; Comware short
names (
GE1/0/1) are mapped to full NetBox names (GigabitEthernet1/0/1) - VLAN membership per port (untagged and tagged, read from the running
configuration) is written to the interface label, e.g.
10or1,20-22; only VLAN-related lines of the configuration are kept in the raw data - LAG members (Aruba CX
lag N, ArubaOS-Switchtrunk … trkN, Comwareport link-aggregation group N) get their LAG in the label, e.g.10,20 (LAG 1), and are assigned to the LAG interface in NetBox (field LAG; only on the same device). Members without own VLAN configuration take the VLANs of their LAG. NetBox Utilities 0.25.0 or later ignores the LAG note when it evaluates VLAN labels - Automatic port mapping when NetBox names differ from the switch (e.g.
5↔1/1/5): equal name, then equal port number, then natural order - Mapping review before the preview: non-obvious port mappings and every LLDP/CDP neighbour can be corrected; a neighbour can be assigned manually to any device of the switch's tenant group. Choices are stored in the profile
- Networks and VLANs in the same review: per network the VRF (global, a VRF of the tenant group or a new one) and whether a missing prefix is created. Network decisions are stored per profile like the VLAN decisions; networks whose prefix exists or that were decided before sit in a collapsed, editable section
- VLAN mapping: switch VLANs are matched to NetBox VLANs of the switch's tenant group by VID (own tenant, site and similar names decide between several); each VLAN can be mapped manually, skipped or created with a name and a tenant of the tenant group of your choice (pre-filled from the switch configuration and the switch's tenant). VLANs can also be ignored on all switches – they are neither created nor assigned and are left out of the labels. VLAN decisions are stored per profile (shared by all its switches); only VLANs that still need a decision are shown, stored and unambiguous ones are in a collapsed section that can be expanded for editing. Mapped VLANs are assigned to the ports (802.1Q mode, untagged/tagged)
- Tenant required: a switch without tenant in NetBox is refused; every created IP address, prefix, VRF, VLAN and cable gets the switch's tenant
- Stacks are detected (Aruba CX VSF, ArubaOS-Switch stacking/VSF, HPE Comware IRF): every member is assigned to its own NetBox device (suggested from the NetBox virtual chassis positions, stored per switch) and gets its own ports; LAGs and VLAN interfaces stay on the switch's device
- Optional: with the NetBox Utilities plugin (0.24.0 or later) a detected stack is also entered as its switch stack (the switch's device as stack switch, the other member devices as members); members entered by hand are kept. Without the plugin this step is skipped
- Optional configuration backup ("Konfiguration als Anhang sichern"): with the netbox-attachments plugin the running configuration is attached to the switch's device as a text file. Passwords, keys and SNMP communities are removed first; a new attachment is only added when the configuration changed (SHA-256 in the description). Older plugin versions (parent on the attachment) and newer ones (separate assignments) are supported; without the plugin the step is skipped with a note
- Cables from LLDP/CDP, also with FQDN system names or via the management IP. Neighbors that report their MAC address as port ID (e.g. access points) are matched by MAC, and a device with a single physical port is cabled there. Wireless interfaces (Wi-Fi, LTE …) are never cable targets. In the review dialog the far-end interface can be chosen per neighbor ("automatisch" shows the interface that would be used); the choice is stored in the profile. Every skipped cable is listed as a note with its reason
- Existing cables are checked against LLDP/CDP: a different far end is reported as a note. Only with the optional "Bestehende Kabel anpassen" (confirmed with a warning, NetBox is the source of truth) the cable is moved to the reported neighbor; such changes are marked with ⚠ in the preview. Cables to patch panels (front/rear ports) and far ends that already have another cable are never changed
- The switch configuration is only changed when "Enable LLDP if needed" is explicitly switched on
- LANCOM switches with the mode-based LCOS SX 3.x CLI (e.g. GS-2326P+) are read
over SSH:
system,port,vlan,ipandlldpmodes with theirshowcommands. Untagged/tagged VLANs follow the egress rule (Access, Hybrid = PVID untagged, Trunk). There is no running-config; the collected outputs are attached as backup. "Enable LLDP if needed" switches ports whose LLDP mode is Disabled/Tx only toenable(not saved) and waits one LLDP interval - One-off import without SSH ("Backup importieren …"): configuration backups
of D-Link DGS-1210 (
config.bin) and Linksys LGS (*.cfgor the containedSNCSR.conf) switches are read offline. Hostname, location, management IP, port descriptions, admin state, untagged/tagged VLANs and VLAN names are taken over; the switch is matched to the NetBox device by its hostname and then synchronized like an SSH result (no LLDP neighbors, hence no cables) The D-Linkconfig.binis attached to the device unchanged (it contains the switch's secrets as stored by the switch); the Linksys configuration is attached as text with secrets removed
Sophos access points (CSV from Sophos Central)
- Loads the access point export of Sophos Central (comma or semicolon, UTF-8 or Windows encoding) and checks it: missing site, duplicate IP, serial number or MAC address
- No tenant to pick up front: existing APs are found in all of NetBox by serial number, MAC address and name; Sophos APs in NetBox that are missing in the export are listed as "only in NetBox" for the tenants the export concerns
- Sophos sites are mapped to NetBox sites (suggested by name, stored per profile); the site is optional – APs without one go to a default site, since NetBox requires a site for every device. The tenant is mandatory and chosen deliberately per Sophos site – it is never preselected. Sophos sites left without site and tenant are ignored (stored per profile) and not transferred
- New APs are created with Sophos device type, role, site, serial number, firmware, interface with MAC and IP address (primary IPv4); existing ones get missing serial numbers and tenants, optionally the Sophos name. Preview before writing
Network scanner (read only)
- Scans IP ranges, networks and host names (
192.0.2.1-254,192.0.2.0/24, up to 4096 addresses) in parallel; "own network" fills in the networks of this computer - Finds hosts by ping (Windows ICMP API, no administrator rights), ARP in the local subnet and TCP ports – hosts that block ping are found as well
- Shows name (reverse DNS and NetBIOS, with workgroup/domain), MAC address, open services from a configurable port list and response time
- Compares every address with NetBox automatically: NetBox object (device or VM) and DNS name next to each IP, with the state "matches", "name differs", "not in NetBox" or "in NetBox, not reachable"; nothing is written to NetBox
- Filters for reachable hosts and deviations; double click or context menu opens HTTP/HTTPS, Remote Desktop, file shares or the IP address in NetBox
Windows clients (agentless via WMI/CIM over WinRM)
- Targets from Active Directory (optional search OU, enabled accounts only,
last logon within N days, include/exclude servers) or as a list of host
names, IP addresses, networks (
192.0.2.0/24) and ranges (192.0.2.10-50) - Sign-in via the Windows credential dialog (domain account with local admin rights, verified against the domain) or with the current Windows session; the password is kept in memory only
- Reads name, manufacturer, model (for Lenovo the model name instead of the machine type), serial number, form factor, operating system with version/build, logged-on user, CPU/RAM and physical network adapters with MAC and IPs
- Parallel queries; unreachable clients stay visible with their AD data, errors come with a concrete hint
- Import as NetBox devices with site, role and tenant; manufacturers, device types and platforms are created when needed, optionally interfaces, MAC and IP addresses — with a preview before writing
- Built-in setup guide: group policy (WinRM, service, firewall), permissions, common errors, check commands and a connection test for single clients
Offline mode (without NetBox)
- "Offline mode (without NetBox)" checkbox in the sidebar — global, independent of the customer profile
- VMs and switches are read without a NetBox connection; switches can then be added manually by name
- Selected VMs, clients or read switches are exported as a JSON file
(
*.nbsync.json) — without passwords, tokens or user names - On a machine with NetBox access, "Load from file …" (VMs, switches and Windows clients pages) loads the file; the import wizard or dry-run preview then runs as usual. Switches are matched by NetBox device ID or name
VRFs & networks
- Create several VRFs or prefixes for one tenant at once
Installation
Run NetBoxSynchronizer-Setup-<version>.exe. The installer
- installs for the current user without administrator rights by default ("for all users" can be selected in the wizard),
- creates a Start menu entry and optionally a desktop shortcut,
- updates an existing installation in place,
- asks on uninstall whether customer profiles and logs should be removed too.
Customer profiles of the predecessor ("NetBox VM Import") are migrated automatically.
Development
py -3 -m venv .venv
.\.venv\Scripts\Activate.ps1
pip install -r requirements-dev.txt
python main.py # start the application
python -m pytest # tests
Project layout:
netbox_sync/
core/ UI-independent logic: configuration, NetBox, VMware/Proxmox, VM import, switches, Windows clients
ui/ Qt interface (PySide6): main window, pages, dialogs, import wizard, theme
resources/ icons
installer/ Inno Setup script
tests/ pytest (parsers, configuration, sync against an in-memory NetBox)
Build & installer
The installer requires Inno Setup 6
(winget install JRSoftware.InnoSetup).
.\build.ps1 # tests, PyInstaller build and installer
.\build.ps1 -SkipInstaller # only dist\NetBoxSynchronizer\
Output: dist\installer\NetBoxSynchronizer-Setup-<version>.exe and the
portable variant dist\portable\NetBox VM Import.exe (runs without
installation; -SkipPortable omits it). The version is set in
netbox_sync/__init__.py.