fix: assign only VLANs of the device's site; show notes prominently
- VLANs of another site stay in the label but are not assigned to ports (NetBox rejects them); one note per device and VLAN instead of an error per port - Preview shows a notes badge and expands switches with notes; notes are also written to the log after the transfer Co-Authored-By: Claude Opus 5.5 <[email protected]>
This commit is contained in:
1 parent
d853f08445
commit
dfe985bb9e
4 files changed
+57
-8
No files matched your search
@@ -596,3 +596,19 @@ def test_cables_to_patch_panels_and_busy_far_ends_are_kept():
|
||||
report = sync_snapshot_to_netbox(nb, switch, snapshot, update_cables=True)
|
||||
assert nb.dcim.cables.updates == []
|
||||
assert any("Gegenstelle hat bereits ein anderes Kabel" in note for note in report["notes"])
|
||||
|
||||
|
||||
def test_vlans_of_another_site_are_only_labelled():
|
||||
nb, switch, snapshot = _numbered_setup()
|
||||
nb.dcim.devices.get(1).site = SimpleNamespace(id=2)
|
||||
nb.ipam.vlans.records += [
|
||||
Record(nb.ipam.vlans, id=110, vid=10, name="MOBILE", tenant=SimpleNamespace(id=7), site=SimpleNamespace(id=1)),
|
||||
Record(nb.ipam.vlans, id=120, vid=20, name="CLIENTS", tenant=SimpleNamespace(id=7), site=None),
|
||||
]
|
||||
report = sync_snapshot_to_netbox(nb, switch, snapshot, create_cables=False)
|
||||
assert report["errors"] == []
|
||||
assert nb.dcim.interfaces.get(1).label == "10" and getattr(nb.dcim.interfaces.get(1), "untagged_vlan", None) is None
|
||||
assert nb.dcim.interfaces.get(2).untagged_vlan == 120, "global VLANs are always assigned"
|
||||
assert [note for note in report["notes"] if "VLAN 10" in note] == [
|
||||
"VLAN 10 „MOBILE“ gehört zu einem anderen Standort als access-01 – nur im Label vermerkt, nicht am Port "
|
||||
"zugewiesen (VLAN global machen, um es zuzuweisen)"]
|
||||